4 ton 410a piston size

2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ...

4 ton 410a piston size. For R22 2.0 ton or R410A 2.5 ton units. .059 opening. Email a Friend. 888-341-7330.

Rheem 4 ton 16 seer split system w/410a R22/410 system Refrigeration dupont handbook piping I have a rheem 80 plus model number rgdc-10ncbjr. the exhaust blower Goodman piston size chart r22Checking the charge on a heat pump in the winter R410a charging chartRheem hvac ac b702 9ce1 4acf.

Product Overview. C35 Indoor Coil C35-48C-2F. Up-flow, full-cased models. 1.5- to 5-ton capacities. Large surface area for high-efficiency operation. Lighter, rifled aluminum tubing, hairpins, distributor and header tubes for improved durability in certain environments. Non-corrosive, UV-resistant polymer drain pan with dual connections.Shopping locally can help small businesses and local economies thrive. Detroit Pistons, Corporate Sponsors Support Small Businesses Through Grants and Promotions. Shopping locally ...Oct 6, 2013 · I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). tHE OLD COIL HAS A #71 piston. The condenser calls for #68 but the specs say it's a 2 1/2 ton orifice. Considering the condenser is a 3 ton this has me a bit confused. Product Description. Features. 10 year warranty on parts & compressor High efficiency scroll compressor. Direct drive multi-speed PSC indoor motor. All aluminum evaporator coil Designed for upflow, downflow, horizontal left and horizontal right installations. Condenser pre-charged with R-410A refrigerant. Insulated air handler cabinet.Chrome/Firefox/Opera/Safari: If you're unhappy with Facebook's new small font size (or other annoyances), userscript Better Facebook gives you over 75 extra options with which you ...

FEM4P4800AL - 4 Ton, R410A, Multi-position ECM Motor Fan Coil, With Piston, Aluminum Tubes, Aluminum Fin . About. About Gemaire; About Heating And Cooling Supply ... Maximum Fuse Size: 15: Metering Device: Piston or Flowrator - Fixed Metering Device: Nominal Electric Heat (kW) 3-30: Number of Speeds: 5 (Five) OPT Code: …R-410A environmentally friendly refrigerant. System Size (Tons): 4 ... you need to throw out your old air conditioner that hasn’t kept you cool in ages and switch it out with the ProDirect 4 Ton 15 SEER Split System A/C Condenser from MRCOOL. ... the piston flow control device manages the speed and volume of the refrigerant as it runs to ...Size matters: Is the U.S. Navy really too small? September 9, 2015. By Zachary Cohen, CNN Updated 6:34 PM ET, Tue September 8, 2015 Sizing up the U.S. …ADP 100000039 - Piston .67, 2 1/2 Ton R22, 3 Ton R410APiston Size 67. Can be used on 2 1/2 Ton R22 Coil or 3 Ton R410a Coil. The store will not work correctly in the case when cookies are disabled. Due to scheduled maintenance, some website features will be unavailable on Saturday 10/29. ...The coil is rated for the higher pressure of R410A, but will work with R22, as well. If using R22 refrigerant, use a #59 piston. If going with Puron (R410A), take the piston out and install a TXV rated for a two ton system with R410A. There is no piston for R410A on this coil, you need to install a TXV. Tim H. Category: HVAC.Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more.Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately

Jan 7, 2014 ... Do not try this at home! HVAC training is required. Town & Country Air, Inc. serves the greater Wilmington, NC area including New Hanover, ...4 - R-410A only. P. Cased - Painted. 6 - R-22 or R ... ¹ (ft²). ² Shipped with Coil. Note: For a properly matched system and piston sizing information, refer to ... assembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any. Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig...

Inspection stickers in lafayette la.

Goodman Piston Coil Chart. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches.NO WARRANTY CLAIM WILL BE HONORED FOR MIX-MATCHED SYSTEMS THAT FAIL TO ADHERE TO THE SPECIFIED PISTON SIZE. WARNING Indoor Unit Indoor Piston Size Piston P/N Note TXV Kit P/N (if used) Outdoor Unit GSX140421A* ASX140421(C,D)* SSX140421(B,C)* All AHRI Matches 0.070 B1789870 TX5N4 1,3 ANX140421A* All AHRI …R-22 R-410A Florator Piston for 60 (Piston Size 93) All Air Handler Model. Cat # : 17N36. Model/Part # : 10000047. Sign in for pricing and availability. Print. Quantity: Add to Cart. Save to List.I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). tHE OLD COIL HAS A #71 piston. The condenser calls for #68 but the specs say it's a 2 1/2 ton orifice. Considering the condenser is a 3 ton this has me a bit confused.Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV useQty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.

Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all HVAC services. Johnson Controls Ducted Systems Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 York International Corporation, 5005 York Drive, Norman, OK 73069 Hello, The cased "A" coil is a Model # TXCO49C4HPCO S/N Z0522LH5G made by American Standard. The 5 Ton condensor is made by Trane and it is Model # 2TTR1060A1000AA and S/N 5311T292F. I did remove the uncased coil from my air handler unit. It was in a housing that was mounted in front of the air handler.Goodman's evaporator coils use a reliable all-aluminum design featuring sine fins and grooved tubes. This design maximizes surface area and optimizes heat transfer for efficient comfort. Secure Cabinet. A galvanized, embossed, and insulated cabinet protects this coil and prevents air leakage, providing superior longevity and efficiency.As the efficiency goes up pressure difference drops. 410 carries more BTU's /LB than 22. When you add all those up it could come out the same. In other words it takes a certain size orifice to move X lb of R-22 equal to Y BTU and that same size orifice just happens to move the right amount of R-410a because the efficiency of the system …Capacity (Tons) Piston Size* (R410a) Piston Kit 1.5 52 MAYORIACHP0052B 2 58 MAYORIACHP0058B 2.5** 063 / 065 MAYORIACHP0063B / 065A 3 70 MAYORIACHP0070B 3.5 75 MAYORIACHP0075B 4 83 MAYORIACHP0083B 5 90 MAYORIACHP0090B. 13 Table 5. Piston Superheat Charging ChartThe 3 to 15 ton Copeland Scroll Digital™ compressors described in this bulletin include the follow compressor model numbers: R-410A R-22 & R-407C ZPD34 to ZPD54K5 ZRD36 to ZRD81KC ZPD61-ZPD83, ZPD91, ZRD94 to ZRD125KC ZPD104, ZPD122KC ZPD103, ZPD120, ZPD137-182KC ZPD and ZRD digital scroll compressors are variableInformation from R410A 13 SEER AC/HP document ©2016 Ingersoll Rand Note: All match ups must be confirmed through AHRI. Condensing Unit Air Handler Piston Size Optional TXV Kit SEER If Preinstalled Piston Replace Required AC M4AC3018B1000NA M4AH3018B100AA C050 MAYTXVACAC1818AA 13 YESCondensing Unit Air Handler / A-Coil Piston Size / TXV Valve Model SEER "Preinstalled Piston" Attached Piston If Preinstalled Piston Replace Required AC M4AC4018C1000AA M4CXC028BA1CAAA 051 / (MAYTXVACHP1830AA) 14 064 068, 058, 057, 050, 069, 051 YES M4CXC030BB1CAAA 051 / (MAYTXVACHP1830AA) 14 063 068, 058, 057, 064, 050,4 Ton Cased Evaporator Coil, Multi-Position, R-410A ... Non-ozone-depleting R-410A refrigerant; California residents: see Proposition 65 Warning. Features and Specification Weight: ... Drain Connection Size: 3/4" Height: 29.75: Length: 20.625: Liquid Line Fitting Type: Sweat or Braze: Liquid Line Size (OD) 3/8" FEM4P4800AL - 4 Ton, R410A, Multi-position ECM Motor Fan Coil, With Piston, Aluminum Tubes, Aluminum Fin Use + and - keys to zoom in and out, arrow keys move the zoomed portion of the image Use + and - keys to zoom in and out, escape key to reset, arrow keys to change image in reset state or move the zoomed portion of the image

Correction on reply # 15 - GSZ140481A piston size should be .078 not .080 Lessons learned the hard way.--Don't let brain think 13 SEER - R22 when working on 14 SEER -R410A -- Make sure new condenser has piston with it. Put piston chart in vehicle-carry it with me. rollandsaxton liked this post.

As the efficiency goes up pressure difference drops. 410 carries more BTU's /LB than 22. When you add all those up it could come out the same. In other words it takes a certain size orifice to move X lb of R-22 equal to Y BTU and that same size orifice just happens to move the right amount of R-410a because the efficiency of the system creates ...Check piston size shipped with indoor unit to see if it matches required indoor piston size. If it does not match, replace indoor piston with correct piston size in table below:[email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert.Guidelines. Available in the following sizes. R-410A 25LB. CYLINDER 100 LB. CYLINDER 850LB. CYLINDER 1450 LB. Pressure-Temp Chart. R-410A. (R-32/125) (50 / 50 wt%) …Installed a Goodman 410a condenser on a r22 evap. Coil do i just change out the piston on txv valve. (57) … read more. Phil. Consultant to Engrs, Govt... Degree, Mech Engr Techno... 13,205 satisfied customers. Just installed 2 new goodman 3.5 ton systems. On startup the. Just installed 2 new goodman 3.5 ton systems.Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.When you add a matching evaporator coil to your system, you get complete home comfort, peak performance and maximized efficiency. Allied Air Enterprises Armstrong Air® Evaporator Coil, Traditional, Series: EC1P-1, 4 ton Nominal Capacity, 1200 to 2000 cfm, Upflow/Downflow Air Flow Type, R-22/R-410A, Piston Expansion Metering Device, 3/8 …

Lodi jail inmate search.

Royal mystic tarot youtube.

Insulated air handler blower & coil compartments. Condenser pre-charged with R410A refrigerant. Suitable for use in manufactured & mobile homes. Integrated Horizontal Drain pans and metal Vertical Drain. Specifications. Condenser Dimensions: H38 1/5" x W30 1/5" x D30 1/5". Air Handler Dimensions: H54 1/2" x W22" x D24".Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.Contact Us. [email protected]. (888) 601–0038. Follow Us. Learn more. ADP 100000036 - Piston .53, 1 1/2 Ton R22, 2 Ton R410APiston Size 53. Can be used on 1 1/2 Ton R22 Coil or 2 Ton R410a Coil.The range on flow rater piston of Goodman 2.5 ton condenser is from .059 to a .078 . Now if you needed a .059 and you put a .078 in it. It can flood back to get the compessor, also. Then vise versa it will starve the evaperator. You need to get the condenser model number and match it up to the evaperator coil model number or your …The Guardian RAC13 - 4 Ton - Air Conditioner - 13 Nominal SEER - Single-Stage - R-410A Refrigerant RAC13J484S21 has been discontinued. Check out Expert's recommended alternatives for another top central air conditioner. ... Check the item dimensions and ensure the items will fit in your vehicle. Bring any straps and other materials that will be [email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert.Cabinet Finish 4 - R-410A only U Uncased P Cased - Painted C Cased - Unpainted Expansion Device Nominal Width or f Gas Furnace F Flowrater A - 14” Width D - 24.5” Width ... Tons Connection Piston Size* (in.) Ship Weight W H A Liquid Suction (lbs) CAUF3137B6 16½" 27" 25" 2½-3 ⅜" ¾" .071 53If it does not match, replace indoor piston with correct piston size. (Indoor pistons are shipped with some outdoor models in the accessory bag and are only qualified for Piston fan coils.) Example fan coils with piston: FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench.Piston r410a Solved 9.4 kg of r-134a fill a 0.7-m3 weighted Answer solved problem. ... 2 1/2 Ton R410A | Gemaire. Check Details. Piston Size Chart R22 Goodman - Best ... ….

ADP - 176799984 - 4 Ton Piston Size 84 R-22/R-410A. Item: ADP176799984 . MFG: 176799984 . loading availability Loading price / EA. Skip to ...I was thinking R22 & 3.5- 13 SEER and I am working on 4.0 - 14 SEER -R410a - That is where I screwed up! Thinking R22. Piston chart for R410A- …Apr 25, 2017 ... ... 410a charging chart can help you fix your ... The orifice size in the piston determines how much liquid refrigerant enters the evaporator coil.20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that requires the other components of the system to be rated for R-410A. For compressor lubrication, the refrigerant requires POE oil.Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig...Information from R410A 14 SEER AC/HP document. Condensing Unit. Air Handler / A-Coil. Piston Size / TXV Valve Model. SEER. "Preinstalled Piston". Attached Piston. If …CE - Carrier EnterpriseIf it does not match, replace indoor piston with correct piston size. (Indoor pistons are shipped with some outdoor models in the accessory bag and are only qualified for Piston fan coils.) Example fan coils with piston: FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench.Mortex coils for manufactured housing are universal R22/R410a. The metering device (piston or TXV) is the key. It is common to replace a R22 condenser with a R410a condenser, keep the evap coil and change piston or TXV to match. The SEER on these suck when new. Disclaimer, I will only change out a manufactured house system if coil and condenser ...Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil. 4 ton 410a piston size, As the efficiency goes up pressure difference drops. 410 carries more BTU's /LB than 22. When you add all those up it could come out the same. In other words it takes a certain size orifice to move X lb of R-22 equal to Y BTU and that same size orifice just happens to move the right amount of R-410a because the efficiency of the system …, Hydraulic Pumps - Hydraulic pumps are capable of pushing large amounts of oil through hydraulic cylinders. Learn about hydraulic pumps and hydraulic pump capabilities. Advertisemen..., piston size dimensions shipping information cabinet width (w)” cabinet depth (d)” cabinet height (h)” shipping weight (lbs) skid r22 r410a min width max width 2 row 3 row 4 row qty de24a* 0.059 0.055 142 21 21 1/2 19 33 36 41 20 de24b* 0.059 0.055 142 21 21 1/2 19 36 39 45 20 de24c* 0.059 0.055 142 21 21 1/2 23 40 46 50 16, Note: “Graphics in this document are for representation only. Actual model may differ in appearance.”. Product Data. 222-1970-1A-EN. Product Specifications. Model No.(a)4TTR5018N1000A 4TTR5024N1000A 4TTR5030N1000A 4TTR5036N1000A POWER CONNS. – V/PH/HZ(b)208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. …, a. Exceptions for air conditioning (cooling only) applications, 1/4" liquid line may be used in: i. 1.5 ton applications for up to 100 equivalent feet (30.5 equivalent meters) with maximum 40’ (12.2 m) vertical lift ii. 2.0 ton applications for up to 75 equivalent feet (22.9 equivalent meters) with maximum 20’ (6.1 m) vertical lift b., Lennox Elite CH35, CH35-51C-2F, 4 Ton, Piston (R410A), Cased Aluminum Horizontal Evaporator Coil. Cat # : 10C38. Model/Part # : CH35-51C-2F. Replacement Available This product has been replaced by Cat# Print. Quantity: Add …, goodman piston size. I bought some left over r22 goodman 13 seer condensor units. A gsc 2 ton and a 2 1/2 ton. Neither of these units had their customary piston connected to the condenser under the electrical panal. I decided to look online and get the piston size but under piston size for these 2 units just have a slash., According to my chart the GSZ14048 takes a .80 piston. Also Goodman does not ship the piston with the 14 SEER condensers. I guess they wanted to save a buck per unit since most have the option for TXV too. You definitely can not count on the correct piston being shipped in the AH or coil either., Correction on reply # 15 - GSZ140481A piston size should be .078 not .080 Lessons learned the hard way.--Don't let brain think 13 SEER - R22 when working on 14 SEER -R410A -- Make sure new condenser has piston with it. Put piston chart in vehicle-carry it with me. rollandsaxton liked this post., Lennox Elite C35, C35-49C-2, 4 Ton, Piston (R410A), Uncased Aluminum Upflow Evaporator Coil. Cat # : 16F44. Model/Part # : C35-49C-2. Replacement Available This product has been replaced by Cat# ... 4 Ton . Metering Device. Piston (R410A) Product Depth. 21.5 Inch . Product Width. 19.5 Inch . Product Height. 28.5 Inch . Cased. …, Buy Goodman GSZ130481 4 Ton, 13 SEER Heat Pump, R-410A Refrigerant. Goodman technical support information, product brochures and more. ... (also called "flow rater" or "piston") in a small bag taped to the side of the heat pump. ... Suction Line Size (OD) 7/8 Inches. Product Dimensions. Width. 29.000000000 Inches. Depth. 29.000000000 …, This manual is also suitable for: View and Download Daikin R-410A technical data manual online. Outdoor units. R-410A air conditioner pdf manual download. Also for: Rxs-g2v1b., Installed a Goodman 410a condenser on a r22 evap. Coil do i just change out the piston on txv valve. (57) … read more. Phil. Consultant to Engrs, Govt... Degree, Mech Engr Techno... 13,205 satisfied customers. Just installed 2 new goodman 3.5 ton systems. On startup the. Just installed 2 new goodman 3.5 ton systems., York still ships an orifice with the condenser; And a schrader for the evap in you use said piston. There is no standard for piston sizing. Each mfr does it their own way. Nordyne uses a 67 for a 3 ton 410 unit for example. ADP says 73 for 3 ton R22., Installed a Goodman 410a condenser on a r22 evap. Coil do i just change out the piston on txv valve. (57) … read more. Phil. Consultant to Engrs, Govt... Degree, Mech Engr Techno... 13,205 satisfied customers. Just installed 2 new goodman 3.5 ton systems. On startup the. Just installed 2 new goodman 3.5 ton systems., NO WARRANTY CLAIM WILL BE HONORED FOR MIX-MATCHED SYSTEMS THAT FAIL TO ADHERE TO THE SPECIFIED PISTON SIZE. WARNING Indoor Unit Indoor Piston Size Piston P/N Note TXV Kit P/N (if used) Outdoor Unit GSX140421A* ASX140421(C,D)* SSX140421(B,C)* All AHRI Matches 0.070 B1789870 TX5N4 1,3 ANX140421A* All AHRI Matches 0.074 B1789874 TX5N4 1,3, A 0.067 orifice is about right for a 3 ton 13SEER R-410A system, or at least really close, depending on which manufacturers chart you look at. Generally you should ignore the orifice size listed on the indoor coil, and go with what the outdoor unit calls for, which in this case is a TXV., 20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that …, Johnson Controls Ducted Systems Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 York International Corporation, 5005 York Drive, Norman, OK 73069 , Mars cares a lot about "fun." Maybe a little too much. Mars—maker of M&Ms, Snickers, Twix, and many more sugary delights—is all about fun. Mars was the first company to have the fu..., Reviews, rates, fees and rewards details for the Bon-Ton Credit Card. Compare to other cards and apply online in seconds. We're sorry, but the Bon-Ton Credit Card may no longer be ..., INSTALLATION INSTRUCTIONS R−410A Split System Air Conditioner 4 421 01 5301 01 UNIT SUPPORT NOTE: Unit must be level ... Check piston size shipped with indoor unit to see if it ... FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench. Hand tighten hex nut, then tighten with wrench 1/2 turn. …, section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) ... (4) b17898-65 piston provided on …, R-410A air conditioner and heat pump split system matches of nominal capacity 90,000 and 120,000 Btuh. This guideline ... Tubing Equivalent Length, Tube Size and Refrigerant..... 6 April 2017. 2 SECTION 1. GENERAL REQUIREMENTS FOR ALL LONG LINE SET APPLICATIONS 1. Equivalent length must be used to determine acceptability of any …, The coil is rated for the higher pressure of R410A, but will work with R22, as well. If using R22 refrigerant, use a #59 piston. If going with Puron (R410A), take the piston out and install a TXV rated for a two ton system with R410A. There is no piston for R410A on this coil, you need to install a TXV. Tim H. Category: HVAC., piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately. , Carrier tech support called and back and said, 56 or 57 - depending on what indoor coil it is. Product Data manual stated - #57 indoor piston and #46 outdoor piston (heating). If you want the manuals, let me know and I will email them to you. Instead of learning the tricks of the trade, learn the trade., no warranty claim will be honored for mix-matched systems that fail to adhere to the specified piston size. warning gsx140301a* asx140301(b,c)* ssx140301(a,b)* awuf 31 & 32 all other ahri matches 0.061 0.065 b1789861 b1789865 tx3n4 tx3n4 2,3 1,3 anx140301a* awuf 31 & 32 all other ahri matches 0.061 0.065 b1789861, Thermostatic Expansion Valves can be mounted in any position on the evaporator coil inlet and are reliable, efficient and virtually trouble-free. Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R-22 (standard) or R-410A (new alternative)., See the coil installation instructions for piston and TXV matches. 13 different models are available to suit a variety of situations and budgets ... 4 - 5 Ton Multi-Position Cased Evaporator Coil (21" W x 21" D x 30" H) Brand: ... Coil Size: 21"W x 30"H x 21"D. Ton: 5. 4. 4 to 5. Airflow: Upflow. Downflow. Horizontal. Refrigerant Type: R-410A ..., Product Overview. CH33 Indoor Coils CH33-44/48B-2F. Minimal air resistance for better performance. 1.5 to 5-ton capacities. Cased. Horizontal configuration. Large-face area coil allows for high efficiency operation. Copper-rifled tubing and enhanced aluminum fins improve transfer. Long lasting, painted galvanized cabinet and plastic drain pans., Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) ... 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use NOTE TO THE INSTALLER: These instructions are for the use of qualified individuals trained and experienced ... for R-410a and green for R-22) to assist with ..., [email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert.